128 |Fox

The Fox Model FT3 Thermal Gas Mass Flow Meter and Temperature Transmitter measures two important process variables in one rugged instrument. The Model FT3 measures gas flow rate in standard units without the need for temperature and pressure compensation. Calibration Validation, using the CAL-V™ and Zero CAL-CHECK™ features, is an in-situ calibration routine that validates the flow meter's accuracy by testing the functionality of the sensor and it associated signal processing circuitry.

FT3
Thermal Mass Flow|Gas Flow

127 |Fox

The Improved Fox Model FT2A Thermal Gas Mass Flow Meter and Temperature Transmitter measures two important process variables in one rugged instrument. The Model FT2A continues to accurately measure gas flow rate in standard units without the need for temperature and pressure compensation. Some additional features available on the FT2A include a standard display, a standard USB port to connect to a PC, and the option of BACnet MS/TP communication protocol.

FT2A
Thermal Mass Flow|Gas Flow

126 |BM TECHNOLOGIES

CW57 for liquids
Applications:
Storage tanks with hazardous working conditions.
Range: until20 m
Accuracy: 3 mm
Process connection: flanges DN50, 80, 100, 150 AISI316L
Antenna: conical Ø 40, 48, 75, 95
Materials: antenna: PTFE
housing: plastic PBT-FR / Aluminium/ AISI
flanges: AISI 316L / PTFE
Working temperature: -40…150°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure: -1 ÷ 16 bar
Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz
Frequency: 26 GHz
Angle emission lobe: Ø50 > 18°; Ø80…150 > 10°;
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltage: 15÷36Vdc
- Absorption: max. 22.5mA
- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input version voltage: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Time of integration: 0÷20s, programmable
Cables entry: 1x PG 13.5
Weight until ~6 kg (depending by flange Ø)

CW57 BM SERIES WAVE COMPACT 26 GHZ - for Liquids
Pulse Radar|Process Controls

125 |BM TECHNOLOGIES

CW56 for liquids and solids
Applications: Level measurement, suitable for highly corrosive media in defined conditions of temperature or pressure.
Range: until 30 m
Accuracy: ± 3 mm
Process connection: G1½ “A flanges DN50, 80, 100, 150 AISI 316L
Antenna: Cones Ø 48, 78, 98, 98 Lengthen, 123
Materials: antenna: AISI 316L / PTFE / PP
housing: plastic PBT-FR / Aluminium / AISI
flanges: AISI 316L / PTFE / PP
Working temperature: -40 ÷400°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure of utilization: -1 ÷ 40 bar
Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz
Frequency: 26 GHz
Angle emission lobe: Ø 40 >22°; Ø 48 >18°; Ø 75 >10° ; Ø 95 >8°
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltages: 15÷36Vdc
- Absorption: 22.5mA
- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input voltages: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Integration time: 0÷20s, programmable
Cables entry: 1x PG 13.5
Weight: until ~5 kg (depending by flange Ø)

CW56 BM SERIES WAVE COMPACT 26 GHZ- For Liquids & Solids
Pulse Radar|Process Controls

124 |BM TECHNOLOGIES

CW55 for liquids
Applications:
Level measurement, suitable for highly corrosive media.
Range: until 10 m
Accuracy: ± 5 mm
Process connection: G1½ “A - NPT
Antenna: Pole
Materials: antenna: PVDF / PTFE
housing: plastic PBT-FR / Aluminium / AISI
flanges: AISI 316L
Working temperature: -40 ÷130°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure of utilization: -1 ÷ 3 bar
Resistance to vibrations: mechanical
vibrations10m/s2, 10÷150Hz
Frequency: 26 GHz
Angle emission lobe: 22°
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltages: 15÷36Vdc
- Absorption: max. 22.5mA
- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input voltages: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Integration time: 0÷20s, programmable
Cables entry: 1x PG 13.5
Weight: ~2 kg

CW55 BM SERIES WAVE COMPACT 26 GHZ- For Liquids
Pulse Radar|Process Controls